Cables

MVCC COVERED CONDUCTOR

Covered conductors consist of a conductor insulated by a covering made of insulating material(s) as protection against accidental contacts with other covered conductors and with grounded parts such as tree branches etc. In comparison with insulated conductors, this covering has reduced thickness, but is sufficient to withstand the phase-to-earth voltage temporarily.

CONSTRUCTION OF MVCC

Conductor: Longitudinally water tight stranded all aluminium alloy (AAAC) or aluminium conductor steel reinforced (ACSR).

A (CONDUCTOR SCREEN) : Water swell able semi-conducting tape (if required) and extruded semi-conducting compound.
B (INNER INSULATION) : XLPE
C (OUTER INSULATION) : UV protected and anti-tracking black coloured XLPE or HDPE.

ANTI-TRACKING PROPERTIES

Anti-tracking property is must for MVCC outer XLPE/HDPE. As per the experience of several international utilities, in the absence of anti-tracking, XLPE or HDPE, MVCC fails within a short time period of 5-6 months. Anti-tracking jacketing has been specially designed to meet the outdoor conditions and performance requirements of 13.8 KV to 34.5 KV distribution networks. The material has an excellent resistance to arc, corrosion inhibitor, fungicide activity, oil resistance, and weather conditions like humidity, pollution, presence of salt in atmosphere etc. There is a special test method for carrying out the tests for the anti-tracking in SS EN 50397-1.

APPLICABLE STANDARDS

SS EN 50397-1, BS EN 50182, IS 398-2, IS 398-4, IEC 61089
However, Lumino can also supply a range of alternative designs to meet customer-specified requirements

SALIENT FEATURES OF MVCC TECHNOLOGY

EASY INSTALLATION

Covered conductors can be installed in an easy and fast manner. Normal pole to pole spacing can be between 50-70 metres; standard poles of bare conductor can be used for covered conductors as the weight of covered conductors is only about 10-12 per cent higher than bare conductor due to insulation. For fast installation even existing poles of bare conductors can be used without changing the cross arms and other fitting with covered conductor and its accessories.

BENEFITS OF MVCC

PHYSICAL PROPERTIES

At a temperature of 20°C (68°F), the density of hard-drawn aluminium has been taken as 2.703 g/cm3 (168.74 lb/cf) and for steel wire 7.8 g/cm3 (485.69 lb/cf).
SR. NO. DESCRIPTION TEMPTATURE
1
Permissible Temp in continuous operation
90°C
194°F
2
Temp in a short circuit (duration up to 5s)
250°C
482°F

Note: The Catalogue Conductor Parameter are informative and can be customized as per Project Requirements

CROSS SECTION DIAGRAM OF COVERED CONDUCTOR